Mechanical Properties
Alloy No.
|
Temper
condition |
Code
|
Tensile Test
|
Bending Test
|
Hardness Test
|
|||||
Thickness
(mm) |
Tensile Strength
(N/mm2) |
Extruding Rate(%)
|
Thickness
(mm) |
Bending
Angle |
Inner Radius
|
Thickness
(mm) |
Vickers
Hardness(HV) |
|||
C1100 |
O
|
C1100.P-O
|
over 0.5~under 30
|
over 195
|
over 35
|
under 2
|
180
![]() |
contact
|
-
|
-
|
C1100.R-O
|
over 0.5~under 3
|
|||||||||
1/4H
|
C1100.P-1/4H
|
over 0.5~under 30
|
215~275
|
over 25
|
under 2
|
180
![]() |
thickness
x 0.5 |
over 0.3
|
55~100
|
|
C1100.R-1/4H
|
over 0.5~under 3
|
|||||||||
1/2H
|
C1100.P-1/2H
|
over 0.5~under 20
|
245~315
|
over 15
|
under 2
|
180
![]() |
thickness
x 1 |
over 0.3
|
75~120
|
|
C1100.R-1/2H
|
over 0.5~under 3
|
|||||||||
H
|
C1100.P-H
|
over 0.5~under 10
|
over 275
|
-
|
under 2
|
180
![]() |
thickness
x 1.5 |
over 0.3
|
over 80
|
|
C1100.R-H
|
over 0.5~under 3
|